| 数据搜索系统,热门电子元器件搜索 |
|
ST10F280 数据表(PDF) 37 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST10F280 数据表(HTML) 37 Page - STMicroelectronics |
|
37 / 186 page ![]() ST10F280 37/186 5.6.5 - Choosing the Baud Rate for the BSL The calculation of the serial Baud rate for ASC0 from the length of the first zero Byte that is received, allows the operation of the bootstrap loader of the ST10F280 with a wide range of Baud rates. However, the upper and lower limits have to be kept, in order to insure proper data transfer. The ST10F280 uses timer T6 to measure the length of the initial zero Byte. The quantization uncertainty of this measurement implies the first deviation from the real Baud rate, the next deviation is implied by the computation of the S0BRL reload value from the timer contents. The formula below shows the association: For a correct data transfer from the host to the ST10F280 the maximum deviation between the internal initialized Baud rate for ASC0 and the real Baud rate of the host should be below 2.5%. The deviation (FB, in percent) between host Baud rate and ST10F280 Baud rate can be calculated via the formula below: Note: Function (FB) does not consider the tolerances of oscillators and other devices supporting the serial communication. This Baud rate deviation is a nonlinear function depending on the CPU clock and the Baud rate of the host. The maxima of the function (FB) increase with the host Baud rate due to the smaller Baud rate pre-scaler factors and the implied higher quantization error (see Figure 8). The minimum Baud rate (BLow in the Figure 8) is determined by the maximum count capacity of timer T6, when measuring the zero Byte, and it depends on the CPU clock. Using the maximum T6 count 216 in the formula the minimum Baud rate can be calculated. The lowest standard Baud rate in this case would be 1200 Baud. Baud rates below BLow would cause T6 to overflow. In this case ASC0 cannot be initialized properly. The maximum Baud rate (BHigh in the Figure 8) is the highest Baud rate where the deviation still does not exceed the limit, so all Baud rates between BLow and BHigh are below the deviation limit. The maximum standard Baud rate that fulfills this requirement is 19200 Baud. Higher Baud rates, however, may be used as long as the actual deviation does not exceed the limit. A certain Baud rate (marked ’I’ in Figure 8) may violate the deviation limit, while an even higher Baud rate (marked ’II’ in Figure 8) stays very well below it. This depends on the host interface. f CPU 32 S0BRL 1 + () × ------------------------------------------------ BST10F280 = S0BR L T6 36 – 72 -------------------- = T6 9 4 --- f CPU B Ho st ----------------- × = , F B B C ontr B Ho st – B C ontr -------------------------------------------- 100 × = % , F B 2.5 ≤ % Figure 8 : Baud Rate Deviation Between Host and ST10F280 BLow 2.5% FB BHigh I II BHOST |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |