| 数据搜索系统,热门电子元器件搜索 |
|
ADE5166 数据表(PDF) 120 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE5166 数据表(HTML) 120 Page - Analog Devices |
|
120 / 148 page ![]() ADE5166/ADE5169/ADE5566/ADE5569 Preliminary Technical Data Rev. PrB | Page 120 of 148 Because the temperature measurement has a resolution of 0.78°C/LSB and the RTC compensation has a resolution of 2ppm/LSB, XTALOS and XTALGain can be processed using XTALOS [7:0] = TEMPADC[7:0]T0 considering the equation of the temperature ADC at 25°C, XTALOS = 0d123, if T0 is given to be 25°C. [] () 14 2 C/LSB 78 . 0 C / ppm 2 0 : 14 × ° × ° × − = k XTALGain where: k is a negative number usually presented with the unit of ppm/°C. XTALGain is an unsigned 15-bit number made up of Register XTALG1 and Register XTALG2. The automatic correction is disabled by default and can be enabled by writing 1 to the MS of the XTALG2 register. When enabled, TEMPCAL can be read but cannot be written by user code. To successfully perform the autocalibration, a temperature reading must first be obtained (see the Temperature Measurement section). This calibration feature is designed to operate in the background to continually maintain an accurate RTC value with changing temperature. It is therefore recommended that temperature measurements be set up to occur automatically in the background through the peripheral ADC strobe period SFR (STRBPER, 0xF9). Background measurements occur every 1, 2, or 8 minutes, depending on the configuration. When the MSB of XTALG2 is set and background temperature readings are initiated, the RTC calibration is performed every time a new temperature measurement is obtained. Note that the temperature and supply delta SFR (DIFFPROG, 0xF3) does not have to be set for the RTC temperature compensation to be operational. Note that because the RTC temperature compensation is designed to operate in the background, it does not affect the temperature, voltage or battery ADC SFRs. These registers are only updated when configured to do so in the temperature and supply delta SFR (DIFFPROG, 0xF3) in background mode, or upon the completion of a single ADC reading initiated by a write to the start ADC measurement SFR (ADCGO, 0xD8). All of the ADC measurements can therefore be used in parallel with the RTC temperature calibration. It should be noted, however, that the frequency of background temperature measurements is restricted by the strobe interval set in the peripheral ADC strobe period (STRBPER, 0xF9) when the RTC temperature compensation was configured. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |