| 数据搜索系统,热门电子元器件搜索 |
|
TNETX15VE 数据表(PDF) 26 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETX15VE 数据表(HTML) 26 Page - Texas Instruments |
|
26 / 113 page ![]() TNETX15VE VLAN-ENGINE ADDRESS-LOOKUP DEVICE SPWS028B – APRIL 1997 – REVISED SEPTEMBER 1997 26 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 management-table lookup interface at 0x0B–0x16 (DIO) BYTE 3 BYTE 2 BYTE 1 BYTE 0 DIO ADDRESS FindVLANID 0x08 Findnode23–Findnode16 Findnode31–Findnode24 Findnode39–Findnode32 Findnode47–Findnode40 0x0C Findport Findnode7–Findnode0 Findnode15–Findnode8 0x10 Findcontrol Findnodeage 0x14 The management-table lookup registers allow the management entity to find information about the node addresses contained in the table. These registers are part of the address lookup/inspection mechanism supported through the DIO (host) interface. An address is fully described by the six bytes of findnode (0xC to 0x11), and one byte of findVLANID (0xB). Duplicate MAC addresses are handled as long as they are made unique by residing on different VLANs. Data about an address is returned in findport (0x12). FIND commands are issued through the findcontrol (0x16) register. They are discussed later in more detail in numerical order. To cause a FIND operation to execute, the host writes to the findcontrol register (0x16). If a generalized FIND command is executed (findfirst), the target address is returned in two parts; the MAC address is returned in six bytes of findnode registers, and the VLANID of that address (actually the VLANID of the port that the addresss resides on) is returned in findVLANID. If a successive FIND command is executed (findnext), the starting point to continue the search is the six bytes of findnode and the one byte of findVLANID. The results are returned in the same registers, overwriting the original values. These registers are read/write between FINDS; the search picks up with the previous FIND (which loaded these registers), or values left by writes from the host interface. If a lookup on an address to check parameters is executed, the data returned corresponds to the value in the six bytes of findnode and one byte of findVLANID when the lookup command was given; the address parameters are posted in the findport register (0x12, 0x13). The FIND operation completion is detected when the command bit is written back to 0 (poll) or when the FNDCPLT interrupt is given. The find register block is discussed later in further detail in numerical order. lookup VLAN tag register, findVLANID at 0x0B (DIO) BIT 7 6 5 4 3 2 1 0 Reserved VLANID Initial Values After Reset 0 0 0 0 0 0 0 0 The findVLANID register returns the associated VLANID code for the node contained in the findnode registers on a lookup logic operation. On a FIND operation with the VLAN modifier active, the FIND logic operation uses this register’s VLANID for searches. FindVLANID register is a read/write register. When the FIND logic operation is operating, this register is locked and writes are ignored. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |