| 数据搜索系统,热门电子元器件搜索 |
|
Z8F021ASH020SC 数据表(PDF) 91 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
Z8F021ASH020SC 数据表(HTML) 91 Page - Zilog, Inc. |
|
91 / 276 page ![]() PS022815-0206 Timers Z8 Encore! XP® 4K Series Product Specification 72 If no Capture event occurs, the timer counts up to the 16-bit Compare value stored in the Timer Reload High and Low Byte registers. Upon reaching the Reload value, the timer generates an interrupt, the count value in the Timer High and Low Byte registers is reset to 0001H and counting resumes. The INPCAP bit in TxCTL0 register is cleared to indicate the timer interrupt is not caused by an input capture event. The steps for configuring a timer for CAPTURE RESTART mode and initiating the count are as follows: 1. Write to the Timer Control register to: – Disable the timer – Configure the timer for CAPTURE RESTART mode by writing the TMODE bits in the TxCTL1 register and the TMODEHI bit in TxCTL0 register. – Set the prescale value. – Set the Capture edge (rising or falling) for the Timer Input. 2. Write to the Timer High and Low Byte registers to set the starting count value (typically 0001H). 3. Write to the Timer Reload High and Low Byte registers to set the Reload value. 4. Clear the Timer PWM High and Low Byte registers to 0000H. This allows user software to determine if interrupts were generated by either a capture event or a reload. If the PWM High and Low Byte registers still contain 0000H after the interrupt, the interrupt was generated by a Reload. 5. Enable the timer interrupt, if appropriate, and set the timer interrupt priority by writing to the relevant interrupt registers. By default, the timer interrupt is generated for both input capture and reload events. If appropriate, configure the timer interrupt to be generated only at the input capture event or the reload event by setting TICONFIG field of the TxCTL0 register. 6. Configure the associated GPIO port pin for the Timer Input alternate function. 7. Write to the Timer Control register to enable the timer and initiate counting. In CAPTURE mode, the elapsed time from timer start to Capture event can be calculated using the following equation: COMPARE Mode In COMPARE mode, the timer counts up to the 16-bit maximum Compare value stored in the Timer Reload High and Low Byte registers. The timer input is the system clock. Upon reaching the Compare value, the timer generates an interrupt and counting continues (the timer value is not reset to 0001H). Also, if the Timer Output alternate function is enabled, Capture Elapsed Time (s) Capture Value Start Value – () Prescale × System Clock Frequency (Hz) ---------------------------------------------------------------------------------------------------- = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |