| 数据搜索系统,热门电子元器件搜索 |
|
Z8F021ASH020SC 数据表(PDF) 92 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
Z8F021ASH020SC 数据表(HTML) 92 Page - Zilog, Inc. |
|
92 / 276 page ![]() PS022815-0206 Timers Z8 Encore! XP® 4K Series Product Specification 73 the Timer Output pin changes state (from Low to High or from High to Low) upon Com- pare. If the Timer reaches FFFFH, the timer rolls over to 0000H and continue counting. The steps for configuring a timer for COMPARE mode and initiating the count are as fol- lows: 1. Write to the Timer Control register to: – Disable the timer – Configure the timer for COMPARE mode. – Set the prescale value. – Set the initial logic level (High or Low) for the Timer Output alternate function, if appropriate. 2. Write to the Timer High and Low Byte registers to set the starting count value. 3. Write to the Timer Reload High and Low Byte registers to set the Compare value. 4. Enable the timer interrupt, if appropriate, and set the timer interrupt priority by writing to the relevant interrupt registers. 5. If using the Timer Output function, configure the associated GPIO port pin for the Timer Output alternate function. 6. Write to the Timer Control register to enable the timer and initiate counting. In Compare mode, the system clock always provides the timer input. The Compare time can be calculated by the following equation: GATED Mode In GATED mode, the timer counts only when the Timer Input signal is in its active state (asserted), as determined by the TPOL bit in the Timer Control register. When the Timer Input signal is asserted, counting begins. A timer interrupt is generated when the Timer Input signal is deasserted or a timer reload occurs. To determine if a Timer Input signal deassertion generated the interrupt, read the associated GPIO input value and compare to the value stored in the TPOL bit. The timer counts up to the 16-bit Reload value stored in the Timer Reload High and Low Byte registers. The timer input is the system clock. When reaching the Reload value, the timer generates an interrupt, the count value in the Timer High and Low Byte registers is reset to 0001H and counting resumes (assuming the Timer Input signal remains asserted). Also, if the Timer Output alternate function is enabled, the Timer Output pin changes state (from Low to High or from High to Low) at timer reset. The steps for configuring a timer for GATED mode and initiating the count are as follows: Compare Mode Time (s) Compare Value Start Value – () Prescale × System Clock Frequency (Hz) ------------------------------------------------------------------------------------------------------- = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |