109 / 275 page ![]() DocID022352 Rev 3 109/275 RM0312 16-bit general purpose timer (TIM2/TIM3) 170 17.3.4 Up-counting mode In up-counting mode, the counter counts from 0 to a user-defined compare value (content of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event, and an update event (UEV) if the UDIS bit is 0 in the TIMx_CR1 register. Figure 22 shows an example of this counting mode. Figure 22. Counter in up-counting mode An update event can also be generated by setting the bit UG in the TIMx_EGR register (by software or by using the trigger controller). The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event will occur until UDIS bit has been written to 0. However, the counter restarts from 0, as well as the counter of the prescaler (but the prescaler division factor does not change). In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event. When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR1 register) is set (depending on the URS bit): The auto-reload shadow register is updated with the preload value (TIMx_ARR), The buffer of the prescaler is reloaded with the preload value (content of the TIMx_PSCR register). The following figures show two examples of the counter behavior for different clock frequencies when TIMx_ARR=36h. In Figure 23 the prescaler divider is set to 2, so the counter clock (CK_CNT) frequency is at half the frequency of the the prescaler clock source (CK_PSC). In Figure 23 the autoreload preload is disabled (ARPE=0), so the shadow register is changed immediately and counter overflow occurs when upcounting reaches 36h. This generates an update event. Counter TIMx_ARR Overflow Overflow Overflow Overflow 0 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |