45 / 244 page ![]() Revision 3.1 45 www.national.com Processor Programming (Continued) 3.3.2.1 Control Registers A map of the Control Registers (CR0, CR2, CR3, and CR4) is shown in Table 3-6 and the bit definitions are given in Table 3-7. (These registers should not be confused with the CRRn registers.) The CR0 register contains system control bits which configure operating modes and indicate the general state of the CPU. The lower 16 bits of CR0 are referred to as the Machine Status Word (MSW). When operating in real mode, any program can read and write the control registers. In protected mode, however, only privilege level 0 (most-privileged) programs can read and write these registers. Table 3-6. Control Registers Map 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8765 43210 CR4 Register Control Register 4 (R/W) RSVD T S C RSVD CR3 Register Control Register 3 (R/W) PDBR (Page Directory Base Register) RSVD 0 0 RSVD CR2 Register Control Register 2 (R/W) PFLA (Page Fault Linear Address) CR1 Register Control Register 1 (R/W) RSVD CR0 Register Control Register 0 (R/W) P G C D N W RSVD A M R S V D W P RSVD N E R S V D T S E M M P P E Machine Status Word (MSW) Table 3-7. CR4-CR0 Bit Definitions Bit Name Description CR4 Register Control Register 4 (R/W) 31:3 RSVD Reserved: Set to 0 (always returns 0 when read). 2TSC Time Stamp Counter Instruction: If = 1 RDTSC instruction enabled for CPL = 0 only; reset state. If = 0 RDTSC instruction enabled for all CPL states. 1:0 RSVD Reserved: Set to 0 (always returns 0 when read). CR3 Register Control Register 3 (R/W) 31:12 PDBR Page Directory Base Register: Identifies page directory base address on a 4 KB page boundary. 11:0 RSVD Reserved: Set to 0. CR2 Register Control Register 2 (R/W) 31:0 PFLA Page Fault Linear Address: With paging enabled and after a page fault, PFLA contains the linear address of the address that caused the page fault. CR1 Register Control Register 1 (R/W) 31:0 RSVD Reserved CR0 Register Control Register 0 (R/W) 31 PG Paging Enable Bit: If PG = 1 and protected mode is enabled (PE = 1), paging is enabled. After changing the state of PG, software must execute an unconditional branch instruction (e.g., JMP, CALL) to have the change take effect. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |