| 数据搜索系统,热门电子元器件搜索 |
|
GXM 数据表(PDF) 46 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
GXM 数据表(HTML) 46 Page - National Semiconductor (TI) |
|
46 / 244 page ![]() www.national.com 46 Revision 3.1 Processor Programming (Continued) 30 CD Cache Disable: If CD = 1, no further cache line fills occur. However, data already present in the cache continues to be used if the requested address hits in the cache. Writes continue to update the cache and cache invalida- tions due to inquiry cycles occur normally. The cache must also be invalidated with a WBINVD instruction to com- pletely disable any cache activity. 29 NW Not Write-Through: If NW = 1, the on-chip cache operates in write-back mode. In write-back mode, writes are issued to the external bus only for a cache miss, a line replacement of a modified line, execution of a locked instruction, or a line eviction as the result of a flush cycle. If NW = 0, the on-chip cache operates in write-through mode. In write-through mode, all writes (including cache hits) are issued to the external bus. This bit cannot be changed if LOCK_NW = 1 in CCR2. 18 AM Alignment Check Mask: If AM = 1, the AC bit in the EFLAGS register is unmasked and allowed to enable align- ment check faults. Setting AM = 0 prevents AC faults from occurring. 16 WP Write Protect: Protects read-only pages from supervisor write access. WP = 0 allows a read-only page to be written from privilege level 0-2. WP = 1 forces a fault on a write to a read-only page from any privilege level. 5NE Numerics Exception: NE = 1 to allow FPU exceptions to be handled by interrupt 16. NE = 0 if FPU exceptions are to be handled by external interrupts. 4RSVD Reserved: Do not attempt to modify, always 1. 3TS Task Switched: Set whenever a task switch operation is performed. Execution of a floating point instruction with TS = 1 causes a DNA fault. If MP = 1 and TS = 1, a WAIT instruction also causes a DNA fault. 2EM Emulate Processor Extension: If EM = 1, all floating point instructions cause a DNA fault 7. 1MP Monitor Processor Extension: If MP = 1 and TS = 1, a WAIT instruction causes Device Not Available (DNA) fault 7. The TS bit is set to 1 on task switches by the CPU. Floating point instructions are not affected by the state of the MP bit. The MP bit should be set to one during normal operations. 0PE Protected Mode Enable: Enables the segment based protection mechanism. If PE = 1, protected mode is enabled. If PE = 0, the CPU operates in real mode and addresses are formed as in an 8086-style CPU. Refer to Section 3.13 “Protection” on page 86. Table 3-7. CR4-CR0 Bit Definitions (Continued) Bit Name Description Table 3-8. Effects of Various Combinations of EM, TS, and MP Bits CR0[3:1] Instruction Type TS EM MP WAIT ESC 0 0 0 Execute Execute 0 0 1 Execute Execute 1 0 0 Execute Fault 7 1 0 1 Fault 7 Fault 7 0 1 0 Execute Fault 7 0 1 1 Execute Fault 7 1 1 0 Execute Fault 7 1 1 1 Fault 7 Fault 7 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |