| 数据搜索系统,热门电子元器件搜索 |
|
PC87366 数据表(PDF) 139 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC87366 数据表(HTML) 139 Page - National Semiconductor (TI) |
|
139 / 240 page ![]() 7.0 WATCHDOG Timer (WDT) (Continued) 139 www.national.com 7.3 WATCHDOG TIMER REGISTERS The WATCHDOG Timer registers at offsets 00h-02h relative to the WATCHDOG base address, are shown in the following register map. The base address is defined by designated registers in the WATCHDOG Timer device configuration register set. The following abbreviations are used to indicate the Register Type: • R/W = Read/Write • R = Read from a specific address returns the value of a specific register. Write to the same address is to a different register. • W=Write • RO = Read Only • R/W1C = Read/Write 1 to Clear. Writing 1 to a bit clears it to 0. Writing 0 has no effect. 7.3.1 WATCHDOG Timer Register Map 7.3.2 WATCHDOG Timeout Register (WDTO) This register holds the programmable timeout period, between 1 and 255 minutes. Writing to this register de-asserts the WDO output and sets the WDO status bit to 1 (inactive). Additionally, writing to this register is interpreted as a command for starting or stopping the WATCHDOG Timer, according to the data written. If a non-zero value is written, the timer is activated (countdown starts). If a non-zero value is written when the counter is running, the timer is immediately reloaded with the new value and starts counting down from the new value. If 00h is written, the timer and its outputs are de-activated. Location: Offset 00h Type: R/W Offset Mnemonic Register Name Type Section 00h WDTO WATCHDOG Timeout R/W 7.3.2 01h WDMSK WATCHDOG Mask R/W 7.3.3 02h WDST WATCHDOG Status RO 7.3.4 03h Reserved Bit 76543210 Name Programmed Timeout Period Reset 00000000 Bit Description 7-0 Programmed Timeout Period. These bits hold the binary value of the timeout period in minutes (1 to 255). A value of 00h halts the counter and forces the outputs to inactive levels. A device reset clears the register to 00h. 00h: Timer and WDO outputs inactive 01h-FFh: Programmed timeout period (in minutes) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |