136 / 276 page ![]() PS022815-0206 Analog-to-Digital Converter Z8 Encore! XP® 4K Series Product Specification 117 3. Write the ADC Control/Status Register 1 to configure the ADC – Write to BUFMODE[2:0] to select SINGLE-ENDED or DIFFERENTIAL mode, as well as unbuffered or buffered mode. – If the alarm function is required, set ALMHEN and/or ALMLEN. – Write the REFSELH bit of the pair {REFSELH, REFSELL} to select the internal voltage reference level or to disable the internal reference. The REFSELL bit is contained in the ADC Control Register 0. 4. Write to the ADC Control Register 0 to configure the ADC for continuous conversion. The bit fields in the ADC Control register may be written simultaneously: – Write to the ANAIN[3:0] field to select from the available analog input sources (different input pins available depending on the device) – Set CONT to 1 to select continuous conversion. – If the internal VREF must be output to a pin, set the REFEXT bit to 1. The internal voltage reference must be enabled in this case. – Write the REFSELL bit of the pair {REFSELH, REFSELL} to select the internal voltage reference level or to disable the internal reference. The REFSELH bit is contained in ADC Control/Status Register 1. – Set CEN to 1 to start the conversions. 5. When the first conversion in continuous operation is complete (after 5129 system clock cycles, plus the 40 cycles for power-up, if necessary), the ADC control logic performs the following operations: – CEN resets to 0 to indicate the first conversion is complete. CEN remains 0 for all subsequent conversions in continuous operation. – An interrupt request is sent to the Interrupt Controller to indicate the conversion is complete. 6. The ADC writes a new data result every 256 system clock cycles. For each completed conversion, the ADC control logic performs the following operations: – Writes the 13-bit two’s complement result to {ADCD_H[7:0], ADCD_L[7:3]}. – If the high and low alarms are disabled, sends an interrupt request to the Interrupt Controller denoting conversion complete. – If the high alarm is enabled and the ADC value is higher than the alarm threshold, generates an interrupt. – If the low alarm is enabled and the ADC value is lower than the alarm threshold, generates an interrupt. 7. To disable continuous conversion, clear the CONT bit in the ADC Control Register to 0. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |