135 / 276 page ![]() PS022815-0206 Analog-to-Digital Converter Z8 Encore! XP® 4K Series Product Specification 116 – If the internal voltage reference must be output to a pin, set the REFEXT bit to 1. The internal voltage reference must be enabled in this case. – Write the REFSELL bit of the pair {REFSELH, REFSELL} to select the internal voltage reference level or to disable the internal reference. The REFSELH bit is contained in the ADC Control/Status Register 1. – Set CEN to 1 to start the conversion. 5. CEN remains 1 while the conversion is in progress. A single-shot conversion requires 5129 system clock cycles to complete. If a single-shot conversion is requested from an ADC powered-down state, the ADC uses 40 additional clock cycles to power up before beginning the 5129 cycle conversion. 6. When the conversion is complete, the ADC control logic performs the following operations: – 13-bit two’s-complement result written to {ADCD_H[7:0], ADCD_L[7:3]}. – CEN resets to 0 to indicate the conversion is complete. – If the High and Low alarms are disabled, an interrupt request is sent to the Interrupt Controller denoting conversion complete. – If the High alarm is enabled and the ADC value is higher than the alarm threshold, an interrupt is generated. – If the Low alarm is enabled and the ADC value is lower than the alarm threshold, an interrupt is generated. 7. If the ADC remains idle for 160 consecutive system clock cycles, it is automatically powered-down. Continuous Conversion When configured for continuous conversion, the ADC continuously performs an analog- to-digital conversion on the selected analog input. Each new data value over-writes the previous value stored in the ADC Data registers. An interrupt is generated after each con- version. In CONTINUOUS mode, ADC updates are limited by the input signal bandwidth of the ADC and the latency of the ADC and its digital filter. Step changes at the input are not immediately detected at the next output from the ADC. The response of the ADC (in all modes) is limited by the input signal bandwidth and the latency. Follow these steps for setting up the ADC and initiating continuous conversion: 1. Enable the desired analog input by configuring the general-purpose I/O pins for alternate function. This action disables the digital input and output driver. 2. Write the ADC High Threshold Register and ADC Low Threshold Register if the alarm function is required. Caution: |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |