| 数据搜索系统,热门电子元器件搜索 |
|
ADE9178 数据表(PDF) 32 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE9178 数据表(HTML) 32 Page - Analog Devices |
|
32 / 122 page ![]() Data Sheet ADE9178 THEORY OF OPERATION analog.com Rev. A | 32 of 122 Table 13. Terminology and Full-Scale Codes Notation Description Value Applicable Registers IFS RMS Current in amperes (ARMS), which gives full-scale signal at ADC input. This is the current that gives full scale at the ADC current (IP) inputs of ±31.25 mV peak to peak. Depends on system parameters. For more details, see the example system configuration. Depends on shunt resistor size. VFS_T Theoretical full-scale RMS voltage in volts (VRMS), which gives full-scale input at ADC input. This is the voltage that gives full scale at the ADC voltage (V1P) inputs of ±1 V peak to peak. Depends on system parameters. Depends on resistor-divider ratio. AUXFS Signal value (RMS) in appropriate units, which gives full-scale value at ADC input. The units can be either voltage or current. This is the voltage/current that gives full scale at the auxiliary ADC input. ±1 V peak to peak for V1P/V2P inputs and ±31.25 mV peak to peak for IP input, which depends on the ADC Mux settings. Depends on system parameters. RMSFS_CODES RMS output register value when full-scale input is applied to the ADC input. 107310840 xRMS, xRMSONE, xRMSHALF, xDIP, xSWELL, xPEAK POWFS_CODES Power output register value when full-scale voltage and current of same phase is applied at the ADC input. 85829040 xWATT, xVA PCFFS_CODES Phase compensation filter (PCF) output for waveform streaming. 6706531 M Meter constant (impls/kWHr), which defines the frequency of the CF pulse output. System Configuration. Supported between 100 and 10000. The format for configuration registers for each feature are given along with description of appropriate features are shown in the following sections. To convert output registers to physical quantities, use the following equations shown in Table 14. Table 14. Conversion Equations Purpose Equation Unit Applicable registers RMS related output calculation XFS RMSFS_CODES ×X (1) XRMS Where, X = xRMS, xRMSONE, xRMSHALF, xDIP, xSWELL, xPEAK Power calculation IFS×VFS_T POWFS_CODES ×X (2) watt, VA Where, X = xWATT, xVA Energy calculation IFS×VFS_T POWFS_CODES × XHI≪13 +XLO 4000 (3) watt × seconds Where, XHI = xWATTHR_xx_HI or xVAHR_HI XLO = xWATTHR_xx_LO or xVAHR_LO Power factor xPF×2−27 APF, BPF, and CPF Period calculation xPERIOD+1 4000×216 (4) seconds xPERIOD, PEN_PERIOD Angle calculation 2πANGL_X_Y×256 xPERIOD+1 −2π (5) radians ANGL_X_Y, where, X and Y are phase voltage or currents. For example, ANGL_AV_BV or ANGL_BI_CI |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |