| 数据搜索系统,热门电子元器件搜索 |
|
ADE9178 数据表(PDF) 5 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE9178 数据表(HTML) 5 Page - Analog Devices |
|
5 / 122 page ![]() Data Sheet ADE9178 SPECIFICATIONS analog.com Rev. A | 5 of 122 SYSTEM SPECIFICATIONS FOR ADE9178, ADE9103, ADE9112, AND ADE9113 VDD = 3.3 V ± 10%, GND = DGND = 0 V, TMIN to TMAX = −40°C to +105°C, TTYP = +25°C, and high-pass filter (HPF) on, unless otherwise noted. Table 1. System Specifications Parameter Min Typ Max Unit Test Conditions/Comments TOTAL ACTIVE ENERGY Measurement Error (3-Phases) Total Active Energy 0.1 % Over a dynamic range of 2000 to 1, power factor (PF) = 1, 10 second accumulation, power offset calibration applied 0.2 % Over a dynamic range of 2000 to 1, power factor (PF) = 1, 10 second accumulation, no power offset calibration applied Total Active Energy Bandwidth 1.65 kHz ADE91xx LPF_BW = 0 TOTAL APPARENT ENERGY Measurement Error (3-Phases) Total Apparent Energy 0.1 % Over a dynamic range of 2000 to 1, power factor (PF) = 1, 10 second accumulation, RMS offset calibration applied 0.6 % Over a dynamic range of 2000 to 1, power factor (PF) = 1, 10 second accumulation, no RMS offset calibration applied RMS MEASUREMENTS Filtered IRMS 0.4 % Over a dynamic range of 2000 to 1, average of 1 sample per line cycle for 1 second, RMS offset calibration applied 0.65 % Over a dynamic range of 2000 to 1, average of 1 sample per line cycle for 1 second, no RMS offset calibration applied Filtered VRMS 0.2 % Over a dynamic range of 2000 to 1, average of 1 sample per line cycle for 1 second, RMS offset calibration applied 0.2 % Over a dynamic range of 2000 to 1, average of 1 sample per line cycle for 1 second, no RMS offset calibration applied IRMS of Half Cycle 2.5 % Over a dynamic range of 1000 to 1, based on a single result, RMS offset calibration applied 2.5 % Over a dynamic range of 1000 to 1, based on a single result, no RMS offset calibration applied VRMS of Half Cycle 1 % Over a dynamic range of 1000 to 1, based on a single result, RMS offset calibration applied 1 % Over a dynamic range of 1000 to 1, based on a single result, no RMS offset calibration applied IRMS of Full Cycle 2 % Over a dynamic range of 1000 to 1, based on a single result, RMS offset calibration applied 2 % Over a dynamic range of 1000 to 1, based on a single result, no RMS offset calibration applied VRMS of Full Cycle 0.5 % Over a dynamic range of 1000 to 1, based on a single result, RMS offset calibration applied 0.5 % Over a dynamic range of 1000 to 1, based on a single result, no RMS offset calibration applied METROLOGY MESUREMENTS Phase Angle Measurement Error 0.5 Degrees Over a dynamic range of 100 to 1, line frequency = 45 Hz to 65 Hz, phase angle = 0° to 360°, HPF on Power Factor Measurement Error 0.005 PF Over a dynamic range of 2000 to 1, power factor (PF)= −1 to 1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |