| 数据搜索系统,热门电子元器件搜索 |
|
ADE9178 数据表(PDF) 44 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE9178 数据表(HTML) 44 Page - Analog Devices |
|
44 / 122 page ![]() Data Sheet ADE9178 THEORY OF OPERATION analog.com Rev. A | 44 of 122 Table 22. Zero-Crossing Use in Other Functions Function Using Zero Crossing ZX Transition Used Corresponding STATUSx Register Bits Selecting Which Phase to Use for Measurement Effect if ZX Does Not Occur ZX Indication in STATUS0 Register1 Negative to positive and positive to negative ZXAI, ZXBI, ZXCI, ZXAV, ZXBV, ZXCV, ZXAUX0, ZXAUX1, ZXAUX2, ZXAUX3, ZXAUX4, ZXAUX5, and ZXCOMB of STATUS0 and STATUS1 registers N/A2 ZXx bit is latched in STATUS1. If cleared, it is not set again. ZXx interrupt does not occur. Zero-Crossing Timeout Negative to positive and positive to negative ZXTOAV, ZXTOBV, and ZXTOCV of STATUS0 and STATUS1 registers N/A2 Zero-crossing timeout is indicated by the ZXTOAV, ZXTOBV, or ZXTOCV bit in the STATUS0 register and an interrupt can be enabled to occur. Phase-Sequence Error Detection Negative to positive only SEQERR of STATUS0 and STATUS1 registers N/A2 If one to two ZX events are missing, SEQERR is generated. If all ZX are missing then SEQERR bit is not set. Energy Accumulation Negative to positive and positive to negative N/A2 ZX_LP_SEL:ZX_SEL[1:0] selects the zero-crossing output used for line-cycle energy accumulation and ZX output pin. Line-cycle accumulation does not update. Note, it is not recommended to use line-cycle accumulation mode (for more details, see Table 30). Line Period Measurement Negative to positive only N/A2 N/A2 Coerced to default value: 0x0050_0000 if ACCMODE.SELFREQ = 0, for a 50 Hz network, 0x0042_AAAA if ACCMODE.SELFREQ = 1, for a 60 Hz network. RMSONE, DIPONE, SWELLONE Negative to positive only STATUS2 register ZX_LP_SEL:LP_SEL[3:2] selects the phase voltage line period used as the basis for these calculations. If the selected line period is invalid because zero crossings are not detected or the calculation results in something outside a 40 Hz to 70 Hz range, the line period used for the calculation is coerced to the default line period: 0x0050_0000 if ACCMODE:SELFREQ = 0, for a 50 Hz network, 0x0042_AAAA if ACCMODE:SELFREQ = 1, for a 60 Hz network. This line period is used to calculate RMSONE and associated events. RMSHALF, DIPHALF, SWELLHALF Negative to positive and positive to negative STATUS3 register N/A2 If bits are set to 1 in the RMSHALF_CONFIG register then the corresponding RMSHALF register value is calculated based on the user- configured half line-cycle period register (USER_PERIOD_HALF). Otherwise, if zero crossing is not detected, the corresponding RMSHALF register value is not updated. DIPHALF and SWELLHALF is not detected in such cases. Angle Measurements Negative to positive only N/A2 N/A2 Does not update, keeps last value. 1 The ZX output from ADE9178 has very high jitter, hence it is not intended for external use. 2 N/A means not applicable. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |