| 数据搜索系统,热门电子元器件搜索 |
|
PC87309VLJ 数据表(PDF) 62 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC87309VLJ 数据表(HTML) 62 Page - National Semiconductor (TI) |
|
62 / 192 page ![]() The Floppy Disk Controller (FDC) (Logical Device 0) 62 www.national.com 11: The polarity of the DENSEL signal is defined by the DENSEL Polarity bit (bit 5) of the SuperI/O FDC configuration register. See page “Bit 5 - DENSEL Polarity Control” on page 30. (Default) TABLE 3-13. DENSEL Encoding Execution Phase Internal registers are written. Result Phase None. 3.7.8 The NSC Command The NSC command can be used to distinguish between the FDC versions and the 82077. Command Phase Execution Phase Result Phase. The result phase byte of the NSC command identifies the floppy disk controller (FDC) as a PC87309 by returning a value of 73h. The 82077 and DP8473 return the value 80h, signifying an invalid command. Bits 3-0 of this result byte are subject to change by NSC, and specify the version of the Floppy Disk Controller (FDC) 3.7.9 The PERPENDICULAR MODE Command The PERPENDICULAR MODE command configures each of the four logical disk drives for perpendicular or conven- tional mode via the logical drive configuration bits 1,0 or 5- 2, depending on the value of bit 7. The default mode is con- ventional. Therefore, if the drives in the system are conven- tional, it is not necessary to issue a PERPENDICULAR MODE command. This command supports the unique FORMAT TRACK and WRITE DATA requirements of perpendicular (vertical) re- cording disk drives with a 4 MB unformatted capacity. Perpendicular recording drives operate in extra high density mode at 1 or 2 Mbps, and are downward compatible with 1.44 MB and 720 KB drives at 500 kbps (high density) and 250 kbps (double density), respectively. If the system includes perpendicular drives, this command should be issued during initialization of the FDC. Then, when a drive is accessed for a FORMAT TRACK or WRITE DATA command, the FDC adjusts the command parame- ters based on the data rate. See TABLE 3-14 on page 63. Precompensation is set to zero for perpendicular drives at any data rate. Perpendicular recording type disk drives have a pre-erase head that leads the read or write head by 200 µm, which translates to 38 bytes at a 1 Mbps data transfer rate (19 bytes at 500 Kbps). The increased space between the two heads requires a larger gap 2 between the address field and data field of a sector at 1 or 2 Mbps. See Perpendicular Format in FIG- URE 3-5 on page 59. A gap 2 length of 41 bytes (at 1 or 2 Mbps) ensures that the preamble in the data field is com- pletely pre-erased by the pre-erase head. Also, during WRITE DATA operations to a perpendicular drive, a portion of gap 2 must be rewritten by the controller to guarantee that the data field preamble has been pre- erased. See TABLE 3-14 on page 63. Command Phase Second Command Phase Byte A hardware reset clears all the bits to zero (conventional mode for all drives). PERPENDICULAR MODE command bits may be written at any time. The settings of bits 1 and 0 in this byte override the logical drive configuration set by bits 5 through 2. If bits 1 and 0 are both 0, bits 5 through 2 configure the logical disk drives as conventional or perpendicular. Otherwise, bits 2 and 0 con- figure them. See TABLE 3-21 on page 72. Bits 1,0 - Group Drive Mode Configuration (GDC) These bits configure all the logical disk drives as con- ventional or perpendicular. If the Overwrite bit (OW, bit 7) is 0, this setting may be overridden by bits 5-2. It is not necessary to issue the FORMAT TRACK com- mand if all drives are conventional. These bits are cleared to 0 by a software reset. 00: Conventional. (Default) Bit 7 Bit 6 DENSEL Pin Definition 0 0 DENSEL low 0 1 DENSEL high 1 0 undefined 1 1 Set by bit 5 of the SuperI/O FDC configuration register at offset F0h. 76543210 00011000 76543210 01110011 76543210 00010010 OW 0 DC3 DC2 DC1 DC0 GDC |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |