| 数据搜索系统,热门电子元器件搜索 |
|
AM79C971VCW 数据表(PDF) 46 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C971VCW 数据表(HTML) 46 Page - Advanced Micro Devices |
|
46 / 265 page ![]() 46 Am79C971 Whenever the Am79C971 controller is the current bus master and a data parity error occurs, SINT (CSR5, bit 11) will be set to 1. When SINT is set, INTA is asserted if the enable bit SINTE (CSR5, bit 10) is set to 1. This mechanism can be used to inform the driver of the sys- tem error. The host can read the PCI Status register to determine the exact cause of the interrupt. The setting of SINT due to a data parity error is not dependent on the setting of PERREN (PCI Command register, bit 6). By default, a data parity error does not affect the state of the MAC engine. The Am79C971 controller treats the data in all bus master transfers that have a parity error as if nothing has happened. All network activity contin- ues. Advanced Parity Error Handling For all DMA cycles, the Am79C971 controller provides a second, more advanced level of parity error handling. This mode is enabled by setting APERREN (BCR20, bit 10) to 1. When APERREN is set to 1, the BPE bits (RMD1 and TMD1, bit 23) are used to indicate parity error in data transfers to the receive and transmit buff- ers. Note that since the advanced parity error handling uses an additional bit in the descriptor, SWSTYLE (BCR20, bits 7-0) must be set to 2 or 3 to program the Am79C971 controller to use 32-bit software structures. The Am79C971 controller will react in the following way when a data parity error occurs: s Initialization block read: STOP (CSR0, bit 2) is set to 1 and causes a STOP_RESET of the device. s Descriptor ring read: Any on-going network activity is terminated in an orderly sequence and then STOP (CSR0, bit 2) is set to 1 to cause a STOP_RESET of the device. s Descriptor ring write: Any on-going network activity is terminated in an orderly sequence and then STOP (CSR0, bit 2) is set to 1 to cause a STOP_RESET of the device. s Transmit buffer read: BPE (TMD1, bit 23) is set in the current transmit descriptor. Any on-going net- work transmission is terminated in an orderly se- quence. s Receive buffer write: BPE (RMD1, bit 23) is set in the last receive descriptor associated with the frame. Terminating on-going network transmission in an order- ly sequence means that if less than 512 bits have been transmitted onto the network, the transmission will be terminated immediately, generating a runt packet. Figure 23. Initialization Block Read In Non-Burst Mode FRAME CLK AD IRDY TRDY C/BE DEVSEL REQ GNT PAR DEVSEL is sampled IADDi 0000 0110 PAR PAR DATA DATA IADDi+4 0000 0110 PAR PAR 1 2345678 10 9 20550D-26 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |