68 / 265 page ![]() 68 Am79C971 Since any valid Ethernet Type field value will always be greater than a normal IEEE 802.3 Length field ( ≥46), the Am79C971 controller will not attempt to strip valid Ethernet frames. Note that for some network protocols, the value passed in the Ethernet Type and/or IEEE 802.3 Length field is not compliant with either standard and may cause problems if pad stripping is enabled. Receive FCS Checking Reception and checking of the received FCS is per- formed automatically by the Am79C971 controller. Note that if the Automatic Pad Stripping feature is en- abled, the FCS for padded frames will be verified against the value computed for the incoming bit stream including pad characters, but the FCS value for a pad- ded frame will not be passed to the host. If an FCS error is detected in any frame, the error will be reported in the CRC bit in RMD1. Receive Exception Conditions Exception conditions for frame reception fall into two distinct categories, i.e., those conditions which are the result of normal network operation, and those which occur due to abnormal network and/or host related events. Normal events which may occur and which are handled autonomously by the Am79C971 controller are basi- cally collisions within the slot time and automatic runt packet rejection. The Am79C971 controller will ensure that collisions that occur within 512 bit times from the start of reception (excluding preamble) will be automat- ically deleted from the receive FIFO with no host inter- vention. The receive FIFO will delete any frame that is composed of fewer than 64 bytes provided that the Runt Packet Accept (RPA bit in CSR124) feature has not been enabled and the network interface is operat- ing in half-duplex mode. This criterion will be met re- gardless of whether the receive frame was the first (or only) frame in the FIFO or if the receive frame was queued behind a previously received message. Abnormal network conditions include: s FCS errors s Late collision Host related receive exception conditions include MISS, BUFF, and OFLO. These are described in the section, Buffer Management Unit. Loopback Operation Loopback is a mode of operation intended for system diagnostics. In this mode, the transmitter and receiver are both operating at the same time so that the control- ler receives its own transmissions. The controller pro- vides two basic types of loopback. In internal loopback mode, the transmitted data is looped back to the re- ceiver inside the controller without actually transmitting any data to the external network. The receiver will move the received data to the next receive buffer, where it can be examined by software. Alternatively, in external loopback mode, data can be transmitted to and received from the external network. Loopback operation is enabled by setting LOOP (CSR15, bit 2) to 1. The mode of loopback operation is dependent on the active network port and on the set- tings of the control bits INTL (CSR15, bit 6), MENDECL (CSR15, bit 10), and TMAULOOP (BCR2, bit 14). The setting of the full-duplex control bits in BCR9 has no ef- fect on the loopback operation. GPSI Loopback Modes When GPSI is the active network port, there are only two modes of loopback operation: internal and external loopback. The settings of MENDECL and TMAULOOP have no effect for this port. When INTL is set to 1, internal loopback is selected. Data coming out of the transmit FIFO is fed directly to the receive FIFO. All GPSI outputs are inactive; inputs are ignored. External loopback operation is selected by setting INTL to 0. Data is transmitted to the network and is expected to be looped back to the GPSI receive pins outside the chip. Collision detection is active in this mode. AUI Loopback Modes When AUI is the active network port, there are three modes of loopback operation: internal with and without MENDEC and external loopback. The setting of TMAU- LOOP has no effect for this port. When INTL and MENDECL are set to 1, internal loop- back without MENDEC is selected. Data coming out of the transmit FIFO is fed directly to the receive FIFO. The AUI transmitter is disabled and signals on the re- ceive and collision inputs are ignored. When INTL is set to 1 and MENDECL is cleared to 0, internal loopback including the MENDEC is selected. Data is routed from the transmit FIFO through the MENDEC back to the receive FIFO. No data is trans- mitted to the network. All signals on the receive and collision inputs are ignored. External loopback operation is selected by setting INTL to 0. The programming of MENDECL has no effect in this mode. The AUI transmitter is enabled and data is transmitted to the network. The Am79C971 controller expects data to be looped back to the receive inputs outside the chip. Collision detection is active in this mode. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |