| 数据搜索系统,热门电子元器件搜索 |
|
AM79C971VCW 数据表(PDF) 104 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C971VCW 数据表(HTML) 104 Page - Advanced Micro Devices |
|
104 / 265 page ![]() 104 Am79C971 bit IEEE station address. It can be overwritten by the host computer and its content has no effect on the op- eration of the controller. The software must copy the station address from the Address PROM space to the initialization block or to CSR12-14 in order for the re- ceiver to accept unicast frames directed to this station. The six bytes of the IEEE station address occupy the first six locations of the Address PROM space. The next six bytes are reserved. Bytes 12 and 13 should match the value of the checksum of bytes 1 through 11 and 14 and 15. Bytes 14 and 15 should each be ASCII “W” (57h). The above requirements must be met in order to be compatible with AMD driver software. APROMWE bit (BCR2, bit 8) must be set to 1 to enable write access to the Address PROM space. Reset Register A read of the Reset register creates an internal soft- ware reset (S_RESET) pulse in the Am79C971 control- ler. The internal S_RESET pulse that is generated by this access is different from both the assertion of the hardware RST pin (H_RESET) and from the assertion of the software STOP bit. Specifically, S_RESET is the equivalent of the assertion of the RST pin (H_RESET) except that S_RESET has no effect on the BCR or PCI Configuration space locations or on the T-MAU. The NE2100 LANCE-based family of Ethernet cards requires that a write access to the Reset register fol- lows each read access to the Reset register. The Am79C971 controller does not have a similar require- ment. The write access is not required and does not have any effect. Note: The Am79C971 controller cannot service any slave accesses for a very short time after a read access of the Reset register, because the internal S_RESET operation takes about 1 µs to finish. The Am79C971 controller will terminate all slave accesses with the as- sertion of DEVSEL and STOP while TRDY is not as- serted, signaling to the initiator to disconnect and retry the access at a later time. Word I/O Mode After H_RESET, the Am79C971 controller is pro- grammed to operate in Word I/O mode. DWIO (BCR18, bit 7) will be cleared to 0. It will then be loaded by the value in the EEPROM. Table 20 shows how the 32 bytes of address space are used in Word I/O mode. All I/O resources must be accessed in word quantities and on word addresses. The Address PROM locations can also be read in byte quantities. The only allowed DWord operation is a write access to the RDP, which switches the device to DWord I/O mode. A read access other than listed in the table below will yield undefined data, a write operation may cause unexpected repro- gramming of the Am79C971 control registers. Table 20 shows legal I/O accesses in Word I/O mode. Double Word I/O Mode After H_RESET, the Am79C971 controller is pro- grammed to operate in Word I/O mode. DWIO (BCR18, bit 7) will be cleared to 0. It will then be loaded by the value in the EEPROM. Table 20 shows how the 32 bytes of address space are used in Word I/O mode. All I/O resources must be accessed in word quantities and on word addresses. The Address PROM locations can also be read in byte quantities. The only allowed DWord operation is a write access to the RDP, which switches the device to DWord I/O mode. A read access other than listed in the table below will yield undefined data, a write operation may cause unexpected repro- gramming of the Am79C971 control registers. Table 23 shows legal I/O accesses in Word I/O mode. Double Word I/O Mode The Am79C971 controller can be configured to operate in DWord (32-bit) I/O mode. The software can invoke the DWIO mode by performing a DWord write access to the I/O location at offset 10h (RDP). The data of the write access must be such that it does not affect the in- tended operation of the Am79C971 controller. Setting the device into 32-bit I/O mode is usually the first oper- ation after H_RESET or S_RESET. The RAP register will point to CSR0 at that time. Writing a value of 0 to CSR0 is a safe operation. DWIO (BCR18, bit 7) will be set to 1 as an indication that the Am79C971 controller operates in 32-bit I/O mode. Table 20. I/O Map In Word I/O Mode (DWIO = 0) Offset No. of Bytes Register 00h - 0Fh 16 APROM 10h 2 RDP 12h 2 RAP (shared by RDP and BDP) 14h 2 Reset Register 16h 2 BDP 18h - 1Fh 8 Reserved Table 21. I/O Map In Word I/O Mode (DWIO = 0) Offset No. of Bytes Register 00h - 0Fh 16 APROM 10h 2 RDP 12h 2 RAP (shared by RDP and BDP) 14h 2 Reset Register 16h 2 BDP 18h - 1Fh 8 Reserved |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |