| 数据搜索系统,热门电子元器件搜索 |
|
TNETV6446AINZWT 数据表(PDF) 104 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TNETV6446AINZWT 数据表(HTML) 104 Page - Texas Instruments |
|
104 / 227 page ![]() PLLV DD18 C2 C1 EMIFilter +1.8V DM644x PLL2 PLL1 0.1µF 0.01µF TMS320DM6446 SPRS283H – DECEMBER 2005 – REVISED SEPTEMBER 2010 www.ti.com Figure 6-13. PLL1 and PLL2 External Connection The minimum CLKIN rise and fall times should also be observed. For the input clock timing requirements, see Section 6.6.3, Clock PLL Electrical Data/Timing (Input and Output Clocks). There is an allowable range for PLL multiplier (PLLM). There is a minimum and maximum operating frequency for MXI/CLKIN, PLLOUT, and the device clocks (SYSCLKs). The PLL Controllers must be configured not to exceed any of these constraints documented in this section (certain combinations of external clock inputs, internal dividers, and PLL multiply ratios might not be supported). Table 6-13. PLLC1 Clock Frequency Ranges CLOCK SIGNAL NAME MIN MAX UNIT MXI/CLKIN(1) 20 30 MHz At 1.2-V CVDD 400 600 MHz PLLOUT At 1.3-V CVDD (-810 only) 400 810 MHz -594 (commercial temp) 600 MHz SYSCLK1 (CLKDIV1 Domain) -810 (commercial temp) 810 MHz A-513 (extended temp) 513 MHz (1) MXI/CLKIN input clock is used for both PLL Controllers (PLLC1 and PLLC2). Table 6-14. PLLC2 Clock Frequency Ranges CLOCK SIGNAL NAME MIN MAX UNIT MXI/CLKIN(1) 20 30 MHz At 1.2-V CVDD 400 900 MHz PLLOUT At 1.3-V CVDD (-810 only) 400 900 MHz (1) MXI/CLKIN input clock is used for both PLL Controllers (PLLC1 and PLLC2). Both PLL1 and PLL2 have stabilization, lock, and reset timing requirements that must be followed. The PLL stabilization time is the amount of time that must be allotted for the internal PLL regulators to become stable after the PLL is powered up (after PLLCTL.PLLPWRDN bit goes through a 1-to-0 transition). The PLL should not be operated until this stabilization time has expired. This stabilization step must be applied after these resets—a Power-on Reset, a Warm Reset, or a Max Reset, as the PLLCTL.PLLPWRDN bit resets to a "1". For the PLL stabliziation time value, see Table 6-15. The PLL reset time is the amount of wait time needed for the PLL to properly reset (writing PLLRST = 0) before bringing the PLL out of reset (writing PLLRST = 1). For the PLL reset time value, see Table 6-15. 104 Peripheral and Electrical Specifications Copyright © 2005–2010, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Link(s): TMS320DM6446 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |