| 数据搜索系统,热门电子元器件搜索 |
|
TNETA1570 数据表(PDF) 55 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETA1570 数据表(HTML) 55 Page - Texas Instruments |
|
55 / 68 page ![]() TNETA1570 ATM SEGMENTATION AND REASSEMBLY DEVICE WITH INTEGRATED 64BIT PCIHOST INTERFACE SDNS033B − JUNE 1995 − REVISED MAY 1996 55 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 PRINCIPLES OF OPERATION parity error (PERR) protocol (continued) The TNETA1570 asserts PERR if the parity-error-response bit (bit 6) in the PCI-configuration-space command register is set and the data-parity-detected bit is set. The assertion of PERR remains valid until the second clock after the cycle in which the error occurred. If a parity error is detected during a transfer involving the TNETA1570, the transaction is allowed to complete unless the TNETA1570 is the master and a target disconnect is detected (i.e. the TNETA1570 will not master abort due to a parity error). system error (SERR) protocol The TNETA1570 sets an internal SERR flag under any of the following conditions: D If an address-parity error is detected on the PCI bus (even if the TDC1570 isnot the target of the transaction) and the parity-error-response bit is set in the PCI-configuration-space command register. D If the TNETA1570 detects PERR asserted while mastering the bus D If the PCI-master-retry counter expires D If the TNETA1570 receives a target abort (disconnect without retry) while mastering the bus D If the TNETA1570 self selects The TNETA1570 asserts SERR if the SERR enable bit (bit 8) in the PCI-configuration-space command register is set and the internal system-error flag is set. The TNETA1570 halts and waits for software or hardware reset after SERR is asserted. The TNETA1570 sets the signaled-system error bit (bit 14) in the PCI-configuration-space status register when SERR is asserted. host-interrupt (INTA) protocol The TDC1570 generates an interrupt to the host by asserting INTA if any of the bits in the internal status register are set and the corresponding status-mask-register bit is also set. PCI-to-UTOPIA data flow for segmentation unit little-endian configuration There are two scenarios for TNETA1570 cell-payload PCI reads from the host memory when the TNETA1570 is configured as a little-endian device. These are 32-bit PCI cell-payload reads and 64-bit PCI cell-payload reads. 32-bit PCI cell-payload reads The top-down order of the following chart represents the time order of 32-bit word reads by the TNETA1570. PCI ADDRESS PCI ADDRESS BITS 31 24 23 16 15 8 7 0 0 ×10 3 2 1 0 0 ×14 7 6 5 4 0 ×18 11 10 9 8 The cell data above is transmitted from the segmentation unit’s UTOPIA bus in the byte order 0, 1, 2, 3, 4, 5, . . . |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |