| 数据搜索系统,热门电子元器件搜索 |
|
AM79C971VCW 数据表(PDF) 138 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C971VCW 数据表(HTML) 138 Page - Advanced Micro Devices |
|
138 / 265 page ![]() 138 Am79C971 The default value of this register is 0000b. This corresponds to a polling interval of 65,536 clock periods (1.966 ms when CLK = 33 MHz). The TXPOL- LINT value of 0000b is created during the microcode initialization routine and, therefore, might not be seen when reading CSR47 af- ter H_RESET or S_RESET. If the user desires to program a value for POLLINT other than the default, then the correct proce- dure is to first set INIT only in CSR0. Then, when the initializa- tion sequence is complete, the user must set STOP (CSR0, bit 2). Then the user may write to CSR47 and then set STRT in CSR0. In this way, the default value of 0000h in CSR47 will be overwritten with the desired user value. If the user does not use the stan- dard initialization procedure (standard implies use of an initial- ization block in memory and set- ting the INIT bit of CSR0), but instead, chooses to write directly to each of the registers that are involved in the INIT operation, then it is imperative that the user also writes all zeros to CSR47 as part of the alternative initialization sequence. Read/Write accessible only when either the STOP or the SPND bit is set. These bits are unaffected by H_RESET, S_RESET, or STOP. CSR48: Receive Poll Time Counter Bit Name Description 31-16 RES Reserved locations. Written as zeros and read as undefined. 15-0 RXPOLL Receive Poll Time Counter. This counter is incremented by the Am79C971 controller microcode and is used to trigger the receive descriptor ring polling operation of the Am79C971 controller. Read/Write accessible only when either the STOP or the SPND bit is set. These bits are unaffected by H_RESET, S_RESET, or STOP. CSR49: Receive Polling Interval Bit Name Description 31-16 RES Reserved locations. Written as zeros and read as undefined. 15-0 RXPOLLINT Receive Polling Interval. This reg- ister contains the time that the Am79C971 controller will wait be- tween successive polling opera- tions. The RXPOLLINT value is expressed as the two’s comple- ment of the desired interval, where each bit of RXPOLLINT approximately represents one clock time period. RXPOL- LINT[3:0] are ignored. (RXPOL- LINT[16] is implied to be a 1, so RXPOLLINT[15] is significant and does not represent the sign of the two’s complement RXPOL- LINT value.) The default value of this register is 0000h. This corresponds to a polling interval of 65,536 clock periods (1.966 ms when CLK = 33 MHz). The RXPOL- LINT value of 0000h is created during the microcode initialization routine and, therefore, might not be seen when reading CSR49 af- ter H_RESET or S_RESET. If the user desires to program a value for RXPOLLINT other than the default, then the correct pro- cedure is to first set INIT only in CSR0. Then, when the initializa- tion sequence is complete, the user must set STOP (CSR0, bit 2). Then the user may write to CSR49 and then set STRT in CSR0. In this way, the default value of 0000h in CSR47 will be overwritten with the desired user value. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |