31 / 93 page ![]() ADP1050 Data Sheet TEMPERATURE LINEARIZATION SCHEME The ADP1050 linearization scheme is based on a combination of a thermistor (R25 = 100 kΩ, 1%), an external resistor (16.5 kΩ, 1%), and the 46 µA current source, preselected for best performance when linearizing measured temperatures in the industrial range. The NTC thermistor that is required must have a resistance of R25 = 100 kΩ, 1%, such as the NCP15WF104F03RC (beta = 4250, 1%). It is recommended that 1% tolerance be used for both the resistor and beta values. The linearization equations show the relationship between the RTD voltage, VRTD (in volts), and temperature reading, T (in degrees Celsius). If T < 104°C, VRTD = (130 − T) × 256 6 . 1 If T ≥ 104°C, VRTD = (156 − T) × 512 6 . 1 where T represents the temperature reading in Register 0x8D. Figure 32 shows the temperature linearization curves. 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 10 20 30 40 50 60 TEMPERATURE (°C) 70 80 90 100 110 120 130 LINEARIZATION VOLT TEMP CURVE ACTUAL VOLT TEMP CURVE Figure 32. Temperature Linearization Scheme Curves Using the internal linearization scheme, the READ_TEMPERA- TURE command (Register 0x8D) returns the current temperature in degrees Celsius. For overtemperature protection, the user can directly set the OT_FAULT_LIMIT command (Register 0x4F) in degrees Celsius. See the OT_FAULT and OT_WARNING section for more information. PMBus PROTECTION COMMANDS VOUT Overvoltage Protection (OVP) The VOUT overvoltage protection feature in the ADP1050 follows PMBus specifications. The limits are programmed in the VOUT_OV_FAULT_LIMIT command (Register 0x40) to correspond to the voltage between 75% and 150% of the nominal output voltage. The responses are programmed using the VOUT_ OV_FAULT_RESPONSE command (Register 0x41). The VOUT_OV_FAULT flag (Register 0x78[5], Register 0x79[5], and Register 0x7A[7]) is set when the voltage reading exceeds the overvoltage limit. In a direct parallel system, multiple power supply units are connected directly in parallel without any OR’ing device. An overvoltage condition in one power supply can raise the common bus voltage, causing the activation of overvoltage protection in the other power supplies connected to the common bus. As a result of this overvoltage protection action, the common bus may fail. The ADP1050 provides a highly flexible, conditional overvoltage protection function for redundant control in a direct parallel system. It consists of an overvoltage detection block, a modulation flag triggering block, and an overvoltage response block (see Figure 33). VOUT_OV_FAULT FLAG DEBOUNCE REG 0xFE26[7:6] VO OVP VS– VOUT_OV_FAULT_RESPONSE REG 0x41 MODULATION VALUE MODULATION THRESHOLD REG 0xFE6B AND AND 0 0 0 0 0 0 EXTENDED VOUT_OV_FAULT_RESPONSE REG 0xFE01[7:4] VOUT_OV_FAULT_LIMIT REG 0x40 VOUT_OV_FAULT REG 0x7A[7] CONDITIONAL OVP ENABLE REG 0xFE6C[0] LARGE_MODULATION REG 0xFE6C[2] DAC Figure 33. VOUT Overvoltage Protection Circuit Implementation Rev. A | Page 30 of 92 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |