52 / 93 page ![]() Data Sheet ADP1050 PMBus COMMAND DESCRIPTIONS BASIC PMBus COMMANDS OPERATION The OPERATION command is used to turn the unit on and off in conjunction with the input from the CTRL pin. It is also used to set the output voltage to the upper or lower voltage margin. The unit stays in the commanded operating mode until a subsequent OPERATION command instructs the device to change to another mode. Table 13. Register 0x01—OPERATION Bits Bit Name/Function R/W Description [7:6] Enable R/W These bits determine the response to the OPERATION command. Bit 7 Bit 6 Description 0 0 Immediate off (no sequencing) 0 1 Soft off (power-down based on the programmed TOFF_DELAY command) 1 0 Unit on 1 1 Reserved [5:4] Margin control R/W These bits set the voltage margin level. Bit 5 Bit 4 Description 0 0 Off 0 1 Margin low 1 0 Margin high 1 1 Reserved [3:0] Reserved R Reserved. ON_OFF_CONFIG The ON_OFF_CONFIG command configures the combination of CTRL pin input and serial bus commands needed to turn the unit on and off, including how the unit responds when power is applied. Table 14. Register 0x02—ON_OFF_CONFIG Bits Bit Name/Function R/W Description [7:5] Reserved R Reserved. 4 Power-up control R/W Controls how the device responds to the OPERATION command. 0 = the unit powers up whenever power is present. 1 = the unit powers up only when commanded by the CTRL pin and the OPERATION command (as programmed in Register 0x02, Bits[3:0]). 3 Command enable R/W Controls how the device responds to the OPERATION command. 0 = ignores the OPERATION command. 1 = requires that the OPERATION command be set to the on state to enable the unit (in addition to the setting of Bit 2). 2 Pin enable R/W Controls how the device responds to the value on the CTRL pin. 0 = ignores the CTRL pin. 1 = requires the CTRL pin to be asserted to enable the unit (in addition to the setting of Bit 3). 1 CTRL pin polarity R/W Sets the polarity for the CTRL pin. 0 = active low. 1 = active high. 0 Power-down delay setting R/W Action to take at power-down. 0 = uses the TOFF_DELAY value (TOFF_FALL is not supported by the ADP1050) to stop the transfer of energy to the output. 1 = turns off the output and stops energy transfer to the output as fast as possible. Rev. A | Page 51 of 92 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |