| 数据搜索系统,热门电子元器件搜索 |
|
ADP1050ACPZ-R7 数据表(PDF) 60 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1050ACPZ-R7 数据表(HTML) 60 Page - Analog Devices |
|
60 / 93 page ![]() Data Sheet ADP1050 VOUT_OV_FAULT_LIMIT The VOUT_OV_FAULT_LIMIT command sets the threshold value for overvoltage protection of the output voltage. Table 36. Register 0x40—VOUT_OV_FAULT_LIMIT Bits Bit Name/Function R/W Description [15:0] Mantissa R/W 16-bit unsigned integer Y value for linear mode format: X = Y × 2N. N is defined by the VOUT_MODE command. Note that the available OV protection limit value must be in the range of 75% to 150% of the nominal output voltage. VOUT_OV_FAULT_RESPONSE The VOUT_OV_FAULT_RESPONSE command determines the fault response for the VOUT_OV_FAULT flag. Table 37. Register 0x41—VOUT_OV_FAULT_RESPONSE Bits Bit Name/Function R/W Description [7:6] Response R/W 00 = continues operation without interruption. 01 = continues operation for the debounce time (Delay Time 1) specified by Register 0xFE26[7:6]. If the fault persists, retry the number of times specified by the retry setting of this command (Bits[5:3]). 10 = shuts down and responds according to the retry setting in Bits[5:3]. 11 = the output is disabled while the fault is present. Operation resumes and the output is enabled when the fault condition no longer exists. [5:3] Retry setting R/W 000 = restart not attempted. The output remains disabled until the fault is cleared. 001 to 110 = attempts to restart the number of times set by these bits. If the ADP1050 fails to restart in the allowed number of retries, the output is disabled and remains off until the fault is cleared. The time between the start of each attempt to restart is set by the Delay Time 2 value in Bits[2:0], along with the delay time unit specified for that particular fault. 111 = attempts to restart continuously, without limitation, until it is commanded off (by the CTRL pin or the OPERATION command, or both), VDD is removed, or another fault condition causes the unit to shut down. [2:0] Delay time R/W These bits set the delay time between the start of each attempt to restart. Bit 2 Bit 1 Bit 0 Delay Time 2 (ms) 0 0 0 252 0 0 1 588 0 1 0 924 0 1 1 1260 1 0 0 1596 1 0 1 1932 1 1 0 2268 1 1 1 2604 VOUT_UV_FAULT_LIMIT The VOUT_UV_FAULT_LIMIT command sets the threshold value for undervoltage protection of the output voltage. Table 38. Register 0x44—VOUT_UV_FAULT_LIMIT Bits Bit Name/Function R/W Bit Name/Function [15:0] Mantissa R/W 16-bit unsigned integer Y value for linear format: X = Y × 2N. N is defined by the VOUT_MODE command. Rev. A | Page 59 of 92 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |