Back Button ADP1050ACPZ-R7 Datasheet HTML 22Page - Analog Devices ADP1050ACPZ-R7 Datasheet HTML 23Page - Analog Devices ADP1050ACPZ-R7 Datasheet HTML 24Page - Analog Devices ADP1050ACPZ-R7 Datasheet HTML 25Page - Analog Devices ADP1050ACPZ-R7 Datasheet HTML 26Page - Analog Devices ADP1050ACPZ-R7 Datasheet HTML 27Page - Analog Devices ADP1050ACPZ-R7 Datasheet HTML 28Page - Analog Devices ADP1050ACPZ-R7 Datasheet HTML 29Page - Analog Devices ADP1050ACPZ-R7 Datasheet HTML 30Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 26 / 93 page
background image
Data Sheet
ADP1050
POWER MONITORING, FLAGS, AND FAULT RESPONSES
The ADP1050 has extensive system and fault condition monitoring
capabilities for the sensed signals. The system monitoring functions
include current, voltage, power, and temperature readings. The
fault conditions include out-of-limit values for current, voltage,
power, and temperature. The limits for the fault conditions are
programmable, and flags are set when the limits are exceeded.
FLAGS
The ADP1050 has an extensive set of flags, including the PMBus
standard flags and manufacturer specific flags, that are set when
certain limits, thresholds are exceeded or certain conditions are
met. A setting of 1 indicates that a fault or warning event has
occurred. A setting of 0 indicates that a fault or warning event
has not occurred.
PMBus Standard Flags
Figure 28 shows a summary of the ADP1050 PMBus standard fault
status registers. The CLEAR_FAULTS command (Register 0x03) is
used to clear all bits in the PMBus status registers (Register 0x78 to
Register 0x7E) simultaneously.
Manufacturer Specific Flags
Register 0xFEA0 to Register 0xFEA2 store the manufacturer
specific flags. These flags include the following:
Housekeeping flags, such as CHIP_PASSWORD_
UNLOCKED, VDD_OV, EEPROM_UNLOCKED, and
CRC_FAULT.
Flags that can be programmed for protection responses,
such as CS3_OC_FAULT and FLAGIN.
Status flags, such as PGOOD, SYNC_LOCKED, CHIP_ID,
PULSE_SKIPPING, modulation, and
SOFT_START_FILTER.
For detailed descriptions of these flags, see the Manufacturer
Specific Fault Flag Registers section.
7
VOUT_OV_FAULT
7
VIN_OV_FAULT
6
VOUT_OV_WARNING
6
VIN_OV_WARNING
5
VOUT_UV_WARNING
5
VIN_UV_WARNING
4
VOUT_UV_FAULT
4
VIN_UV_FAULT
3
VOUT_MAX WARNING
15
VOUT
3
VIN_LOW
2
TON_MAX_FAULT
14
IOUT
2
IIN_OC_FAST_FAULT
1
TOFF_MAX_WARNING
13
INPUT
1
IIN_OC_WARNING
0
VOUT TRACKING ERROR
12
MFR_SPECIFIC
0
PIN_OP_WARNING
11
POWER_GOOD
10
FANS
9
OTHER
8
UNKNOWN
7
IOUT_OC_FAULT
7
MANUFACTURER DEFINED
6
IOUT_OC_LV_FAULT
6
MANUFACTURER DEFINED
5
IOUT_OC_WARNING
5
MANUFACTURER DEFINED
4
IOUT_UC_FAULT
4
MANUFACTURER DEFINED
3
CURRENT SHARE FAULT
3
MANUFACTURER DEFINED
2
IN POWER LIMITING MODE
7
BUSY
2
MANUFACTURER DEFINED
1
POUT_OP_FAULT
6
POWER_OFF
1
MANUFACTURER DEFINED
0
POUT_OP_WARNING
5
VOUT_OV_FAULT
0
MANUFACTURER DEFINED
4
IOUT_OC_FAULT
3
VIN_UV_FAULT
2
TEMPERATURE
1
CML
7 OT_FAULT
0
NONE OF THE ABOVE
7
FAN 1 FAULT
6 OT_WARNING
6
FAN 2 FAULT
5 UT_WARNING
5
FAN 1 WARNING
4 UT_FAULT
4
FAN 2 WARNING
3 RESERVED
3
FAN 1 SPEED OVERRIDE
2 RESERVED
2
FAN 2 SPEED OVERRIDE
1 RESERVED
1
AIR FLOW FAULT
0 RESERVED
0
AIR FLOW WARNING
7
CMD_ERR
7
RESERVED
7
FAN 3 FAULT
6
DATA_ERR
6
RESERVED
6
FAN 4 FAULT
5
PACKET ERROR CHECK FAILED
5
INPUT A FUSE/BREAKER FAULT
5
FAN 3 WARNING
4
MEMORY FAULT DETECTED
4
INPUT B FUSE/BREAKER FAULT
4
FAN 4 WARNING
3
PROCESSOR FAULT DETECTED
3
INPUT A OR’ING DEVICE FAULT
3
FAN 3 SPEED OVERRIDE
2
RESERVED
2
INPUT B OR’ING DEVICE FAULT
2
FAN 4 SPEED OVERRIDE
1
COMM_ERR
1
OUTPUT OR’ING DEVICE FAULT
1
RESERVED
0
OTHER MEMORY OR LOGIC FAULT
0
RESERVED
0
RESERVED
STATUS_OTHER
STATUS_IOUT (REG 0x7B)
STATUS_VOUT (REG 0x7A)
STATUS_TEMPERATURE (REG 0x7D)
STATUS_WORD (REG 0x79)
(UPPER BYTE OF STATUS_WORD)
STATUS_FANS_3_4
STATUS_INPUT (REG 0x7C)
STATUS_MFR_SPECIFIC
STATUS_FANS_1_2
STATUS_CML (REG 0x7E)
STATUS_BYTE (REG 0x78)
(LOWER BYTE OF STATUS_WORD)
Figure 28. Summary of the Fault Status Registers (Only the Commands in Black Are Supported by the ADP1050; the Commands in Gray are Not Supported.)
Rev. A | Page 25 of 92



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com