72 / 168 page ![]() Real-Time Clock (RTC) and Advanced Power Control (APC) 72 www.national.com Power On This is the normal state when the PC87570 is powered on. This state may be initiated by various events in addition to physically switching the system on. The PC system and the PC87570 device are powered by VCC. Note: The APC does not function when the 32.768 KHz oscillator is not running. 6.5.4 System Power Switching Logic In the Power On state, the APC is powered by VCC. If VCC falls to the level of VCCON, the APC enters the Power Off state and switches to VBAT. When power returns after power-off, the APC enables the generation of an APC-ON interrupt after a delay of 1 sec- ond. If VBAT falls below VLOWBAT, the oscillator, timekeeping functions and APC cease functioning. If neither VCC or VBAT is available, the system goes to No Power state. It is initialized when it leaves this state. 6.5.5 APC-ON/APC-OFF Interrupt Signals The APC checks when activation conditions are met, and generates the APC-ON/APC-OFF interrupt signals accord- ingly. The APC-ON/APC-OFF interrupt signals are active- high pulses. APC-ON interrupt is generated, when: • Time Match Enable bit (bit 0 of APCR2) is 1 and there is a match between the RTC and the time specified in the pre-determined date registers. User software must ensure unused date/time fields are coherent to ensure a reliable comparison of valid bits. • RING Enable bit (bit 3 of APCR2) is 1 and one of the fol- lowing occurs: — Bit 2 of APCR2 is 0 and a high-to-low transition is de- tected on the RING input pin. — Bit 2 0f APCR2 is 1 and a train of pulses is detected on the RING input pin. APC-OFF interrupt is generated, when: q A 1 is written to Software Off Command bit (bit 5 of APCR1). 6.5.6 Entering Power States Power Up When power is first applied to the RTC, the APC registers are initialized to the default values defined in APCR1, APCR2 and APSR. See Table 6-5. This situation is defined by the appearance of VBAT or VCC with no previous power. The APC powers-up when the RTC supply is applied from any source. It is in Power On state only when VCC is ap- plied. Power Off The APC is in Power Off state when it is powered by VBAT. Upon entering Power Off state, the following occurs: • The RING pin (for detecting telephone line incoming sig- nals for fax, modem or voice communication) is masked (high). The signal remain masked until 1 second after exit from Power Off state (i.e., 1 second after switching from VBAT to VCC).. When the 1 second delay expires, new events can gen- erate the APC-ON interrupt. In addition, if a time match occurs during Power Off, the APC “remembers” to send an APC-ON interrupt. q In case Power Off was entered before a host Software Off Command was executed, an APC-ON interrupt is generated for RING and/or predetermined wake-up match events detected prior to entering Power Off state. 6.5.7 Predetermined Wake-Up The second, minute and hour values of the pre-determined wake-up times are contained in the Seconds Alarm, Minutes Alarm and Hours Alarm registers respectively (register off- sets 01, 03 and 05 in all banks). The Day of Week, Date of Month Month, Year and Century of the pre-determined date is held in Bank 2, registers, offsets 43h-46h and 48h. These eight registers are compared with the Seconds, Minutes, Hours, Day of Week, Date of Month, Month, Year and Cen- tury registers correspondingly (register offsets 00, 02, 04, 06, 07, 08, 09 in all banks and register offset 48 in Bank 1). 6.5.8 Ring Signal Event An incoming telephone call is an event that may generate an APC-ON interrupt in order to deal with a pending incom- ing voice, fax or modem communication. The PC87570 can detect a RING pulse falling edge, or a RING pulse train with a frequency of at least 16 Hz that lasts at least 0.19 seconds. When APCR2.RPTDM is set, the APC is in a RING pulse train detection mode and the existence of falling edges on RING is monitored in time slots of 62.5 ms (16 Hz cycle time). A RING pulse train detect event occurs if falling edge(s) of RING are detected in three consecutive time slots, following a time slot in which no falling edge of RING is detected. This method of detecting a RING pulse train filters out (does not detect) a RING pulse train of less then 11 Hz, might de- tect a RING pulse train of 11 Hz to 16 Hz, and guarantees detection of a RING pulse train of at least 16 Hz. If APCR2.RPTDM is cleared, a single falling edge on the RING input will generate a RING wakeup event. 6.6 APC REGISTERS The APC registers reside in the APC Bank 2 memory. The RAM Lock register also resides in this bank. See Table 6-9 on page 75. The APC control registers are not affected by system reset. They are initialized to 0 only when power is applied for the first time; i.e., application of either VBAT or VCC, when no previous voltage is present. Table 6-6. APC Control Registers Offset Mnemonic Register Name 40h APCR1 APC Control Register 1 41h APCR2 APC Control Register 2 42h APSR APC Status Register 47h RLR RAM Lock Register |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |