| 数据搜索系统,热门电子元器件搜索 |
|
AD9546/PCBZ 数据表(PDF) 90 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9546/PCBZ 数据表(HTML) 90 Page - Analog Devices |
|
90 / 205 page ![]() AD9546 Data Sheet Rev. 0 | Page 90 of 205 tCARRIER (8 + x) × tCARRIER K × (8 + x) × tCARRIER tGRID Figure 65. Grid Timing Diagram DEMODULATOR SYNCHRONIZATION The demodulators expect modulation events to occur at regular periodic intervals, tGRID, with tGRID comprising an integer number of tCARRIER periods (see Figure 65) such that tGRID = K × (8 + x) × tCARRIER where: K is an integer K ≥ 1. x is an integer with x ≥ 0. Essentially, the value of x relates to the divide ratio, R, of the reference divider as follows: R = 8 + x The net effect is that the reference divider produces an output clock of period, tCARRIER × (8 + x). The reference TDC time stamps the rising edge of each divider output clock cycle with K time stamps occurring in each tGRID period. When the demodulator identifies a modulation event within the carrier signal, it generates a demodulator clock pulse with timing according to Figure 64. The demodulator clock pulse synchronizes the reference divider and causes the reference TDC to tag the associated time stamp (see Figure 62), which creates a fixed timing relationship between incoming modula- tion events and the occurrence of tagged time stamps. Specifically, every Kth time stamp (see Figure 65) is a tagged time stamp. The demodulator denotes the next rising edge of the carrier following the modulation event as the base edge. The user can set the timing of the demodulator clock pulse to occur a predefined number of tCARRIER periods after the base edge via the 2-bit unsigned bit field comprising Bits[5:4] in Register M per the register legend in Figure 62. The decimal value of this bit field, 0 (default), 1, 2, or 3, corresponds to the desired synchronization edge in Figure 64. The user must program a bit field value other than the default value of zero (Bits[5:4] = 0 is not supported). If a modulation event occurs off grid or the modulation rate changes to a new tGRID period, the demodulator must resynchronize. The demodulator requires at least three tCARRIER periods (including the first modulated cycle) to resynchronize when Bit 6 in Register M per the register legend in Figure 62 is Logic 0 and at least eight tCARRIER periods when Bit 6 is Logic 1. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |