36 / 104 page ![]() AD9547 Rev. 0 | Page 36 of 104 Note that history accumulation timer = 0 should not be pro- grammed because it may cause improper device operation. The control logic performs a calculation of the average tuning word during the TAVG interval and stores the result in the holdover history register (Address 0x0D14 to Address 0x0D19). Compu- tation of the average for each TAVG interval is independent of the previous interval (that is, the average is a memoryless average as opposed to a true moving average). In addition, at the end of each TAVG interval, the device generates an internal strobe pulse. The strobe pulse sets the history updated bit in the IRQ monitor register (assuming that the bit is enabled via the IRQ mask register). Furthermore, the strobe pulse is available as an output signal via the multifunction pins (see the Multifunction Pins (M0 to M7) section). History accumulation begins when the device switches to a new reference. By default, the device clears any previous history when it switches to a new reference. Furthermore, the user can clear the tuning word history under software control using Bit 2 of Register 0x0A03 or under hardware control via the multifunction pins (see the Multifunction Pins (M0 to M7) section). However, the user has the option of programming the device to retain (rather than clear) the old history by setting the persistent history bit (Register 0x031B, Bit 3). When the tuning word history is nonexistent (that is, after a power-up, reset, or switchover to a new reference with the persistent history bit cleared), the device waits for the history accumulation timer (TAVG) to expire before storing the first history value in the holdover history register. In cases where TAVG is quite large (4½ hours, for example), a problem arises in that the first averaged result does not become available until the full TAVG interval passes. Thus, it is possible that as much as 4½ hours can elapse before the first averaged result is available. If the device must switch to holdover during this time, a tuning word history is not available. To alleviate this problem, the user can access the incremental average bits in the history mode register (Register 0x031B, Bits[2:0]). If the history has been cleared, this 3-bit value, K (0 ≤ K ≤ 7), specifies the number of intermediate averages to take during the first, and only the first, TAVG interval. When K = 0, no intermediate averages are calculated; therefore, the first average occurs after Interval TAVG (the default operating mode). However, if K = 4, for example, four intermediate averages are taken during the first TAVG interval. These average computations occur at TAVG/16, TAVG/8, TAVG/4, TAVG/2, and TAVG (note that the denominator exhibits a sequence of powers of 2 beginning with TAVG/2K). The calculation of inter- mediate averages occurs only during the first TAVG interval. All subsequent average computations occur at evenly spaced intervals of TAVG. LOOP CONTROL STATE MACHINE The loop control state machine is responsible for monitoring, initiating, and sequencing changes to the DPLL loop. Generally, it automatically controls the transition between input references and the entry and exit of holdover mode. In controlling loop state changes, the state machine also arbitrates the application of new loop filter coefficients, divider settings, and phase detector offsets based on the profile settings. The user can manually force the device into holdover or free-run mode via the loop mode register (Address 0x0A01), as well as force the selection of a specific input reference. Switchover Switchover occurs when the loop controller switches directly from one input reference to another. Functionally, the AD9547 handles a reference switchover by briefly entering holdover mode then immediately recovering. During the switchover event, however, the AD9547 preserves the status of the lock detectors in order to avoid phantom unlock indications. Holdover The holdover state of the DPLL is an open-loop operating mode; that is, the device no longer operates as a closed-loop system. Instead, the output frequency remains constant and is dependent on the device programming and availability of the tuning word history as explained in the following paragraphs. If a tuning word history exists (see the Frequency Tuning Word History section), the holdover frequency is the average frequency just prior to entering the holdover state. If there is no tuning word history, the holdover frequency depends on the state of the single sample fallback bit in the history mode register (Register 0x031B, Bit 4). If the single sample fallback bit is Logic 0, the holdover frequency is the frequency defined in the free-running frequency tuning word register (Address 0x0300 to Address 0x0305). If the single sample fallback bit is Logic 1, the holdover frequency is the last instantaneous frequency output by the DDS just prior to the device entering holdover mode (note that this is not the average frequency prior to holdover). The initial holdover frequency accuracy depends on the loop bandwidth of the DPLL and the time elapsed to compute a tuning word history. The longer the historical average, the more accurate the initial holdover frequency (assuming a drift-free system clock). Furthermore, the stability of the system clock establishes the stability and long-term accuracy of the holdover output frequency. Another consideration is the 48-bit frequency tuning resolution of the DDS and its relationship to fractional frequency error, ΔfO/fO. O S O O f f f f 49 2 = Δ In this equation, fS is the sample rate of the output DAC and fO is the DDS output frequency. The worst-case scenario is maximum fS (1 GHz) and minimum fO (62.5 MHz), which yields ΔfO/fO = 2.8 × 10−14, which is less than one part in ten trillion. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |