| 数据搜索系统,热门电子元器件搜索 |
|
ZUSBOPTSC01ZACG 数据表(PDF) 90 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
ZUSBOPTSC01ZACG 数据表(HTML) 90 Page - Zilog, Inc. |
|
90 / 282 page ![]() PS022827-1212 P R E L I M I N A R Y Operation Z8 Encore! XP® F082A Series Product Specification 73 – Set the prescale value – If using the Timer Output alternate function, set the initial output level (High or Low) 2. Write to the Timer High and Low Byte registers to set the starting count value (usually 0001H ). This action only affects the first pass in CONTINUOUS Mode. After the first timer Reload in CONTINUOUS Mode, counting always begins at the reset value of 0001H. 3. Write to the Timer Reload High and Low Byte registers to set the reload value. 4. Enable the timer interrupt (if appropriate) and set the timer interrupt priority by writ- ing to the relevant interrupt registers. 5. Configure the associated GPIO port pin (if using the Timer Output function) for the Timer Output alternate function. 6. Write to the Timer Control Register to enable the timer and initiate counting. In CONTINUOUS Mode, the system clock always provides the timer input. The timer period is computed via the following equation: If an initial starting value other than 0001H is loaded into the Timer High and Low Byte registers, use the ONE-SHOT Mode equation to determine the first time-out period. COUNTER Mode In COUNTER Mode, the timer counts input transitions from a GPIO port pin. The timer input is taken from the GPIO port pin Timer Input alternate function. The TPOL bit in the Timer Control Register selects whether the count occurs on the rising edge or the falling edge of the Timer Input signal. In COUNTER Mode, the prescaler is disabled. The input frequency of the Timer Input signal must not exceed one-fourth the system clock frequency. Further, the high or low state of the input signal pulse must be no less than twice the system clock period. A shorter pulse may not be captured. Upon reaching the reload value stored in the Timer Reload High and Low Byte registers, the timer generates an interrupt, the count value in the Timer High and Low Byte registers is reset to 0001H and counting resumes. Also, if the Timer Output alternate function is CONTINUOUS Mode Time-Out Period (s) Reload Value Prescale System Clock Frequency (Hz) ------------------------------------------------------------------------ = Caution: |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |