| 数据搜索系统,热门电子元器件搜索 |
|
ZUSBOPTSC01ZACG 数据表(PDF) 98 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
ZUSBOPTSC01ZACG 数据表(HTML) 98 Page - Zilog, Inc. |
|
98 / 282 page ![]() PS022827-1212 P R E L I M I N A R Y Operation Z8 Encore! XP® F082A Series Product Specification 81 3. Write to the Timer Reload High and Low Byte registers to set the reload value. 4. Clear the Timer PWM High and Low Byte registers to 0000H. This allows the soft- ware to determine if interrupts were generated by either a capture event or a reload. If the PWM High and Low Byte registers still contain 0000H after the interrupt, the interrupt was generated by a Reload. 5. Enable the timer interrupt, if appropriate and set the timer interrupt priority by writing to the relevant interrupt registers. By default, the timer interrupt is generated for both input capture and reload events. If appropriate, configure the timer interrupt to be gen- erated only at the input capture event or the reload event by setting TICONFIG field of the TxCTL0 Register. 6. Configure the associated GPIO port pin for the Timer Input alternate function. 7. Write to the Timer Control Register to enable the timer and initiate counting. In CAPTURE Mode, the elapsed time from timer start to Capture event can be calculated using the following equation: COMPARE Mode In COMPARE Mode, the timer counts up to the 16-bit maximum Compare value stored in the Timer Reload High and Low Byte registers. The timer input is the system clock. Upon reaching the Compare value, the timer generates an interrupt and counting continues (the timer value is not reset to 0001H). Also, if the Timer Output alternate function is enabled, the Timer Output pin changes state (from Low to High or from High to Low) upon Compare. If the Timer reaches FFFFH, the timer rolls over to 0000H and continue counting. Observe the following steps for configuring a timer for COMPARE Mode and initiating the count: 1. Write to the Timer Control Register to: – Disable the timer – Configure the timer for COMPARE Mode – Set the prescale value Capture Elapsed Time (s) Capture Value Start Value – Prescale System Clock Frequency (Hz) --------------------------------------------------------------------------------------------------- = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |