| 数据搜索系统,热门电子元器件搜索 |
|
ZUSBOPTSC01ZACG 数据表(PDF) 91 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
ZUSBOPTSC01ZACG 数据表(HTML) 91 Page - Zilog, Inc. |
|
91 / 282 page ![]() PS022827-1212 P R E L I M I N A R Y Operation Z8 Encore! XP® F082A Series Product Specification 74 enabled, the Timer Output pin changes state (from Low to High or from High to Low) at timer Reload. Observe the following steps for configuring a timer for COUNTER Mode and initiating the count: 1. Write to the Timer Control Register to: – Disable the timer. – Configure the timer for COUNTER Mode. – Select either the rising edge or falling edge of the Timer Input signal for the count. This selection also sets the initial logic level (High or Low) for the Timer Output alternate function. However, the Timer Output function is not required to be enabled. 2. Write to the Timer High and Low Byte registers to set the starting count value. This only affects the first pass in COUNTER Mode. After the first timer Reload in COUN- TER Mode, counting always begins at the reset value of 0001H. In COUNTER Mode the Timer High and Low Byte registers must be written with the value 0001H. 3. Write to the Timer Reload High and Low Byte registers to set the reload value. 4. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing to the relevant interrupt registers. 5. Configure the associated GPIO port pin for the Timer Input alternate function. 6. If using the Timer Output function, configure the associated GPIO port pin for the Timer Output alternate function. 7. Write to the Timer Control Register to enable the timer. In COUNTER Mode, the number of Timer Input transitions since the timer start is com- puted via the following equation: COMPARATOR COUNTER Mode In COMPARATOR COUNTER Mode, the timer counts input transitions from the analog comparator output. The TPOL bit in the Timer Control Register selects whether the count occurs on the rising edge or the falling edge of the comparator output signal. In COMPAR- ATOR COUNTER Mode, the prescaler is disabled. COUNTER Mode Timer Input Transitions Current Count Value-Start Value = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |