| 数据搜索系统,热门电子元器件搜索 |
|
ZUSBOPTSC01ZACG 数据表(PDF) 101 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
ZUSBOPTSC01ZACG 数据表(HTML) 101 Page - Zilog, Inc. |
|
101 / 282 page ![]() PS022827-1212 P R E L I M I N A R Y Operation Z8 Encore! XP® F082A Series Product Specification 84 – Set the Capture edge (rising or falling) for the Timer Input 2. Write to the Timer High and Low Byte registers to set the starting count value (typi- cally 0001H). 3. Write to the Timer Reload High and Low Byte registers to set the Compare value. 4. Enable the timer interrupt, if appropriate and set the timer interrupt priority by writing to the relevant interrupt registers.By default, the timer interrupt are generated for both input capture and reload events. If appropriate, configure the timer interrupt to be gen- erated only at the input capture event or the reload event by setting TICONFIG field of the TxCTL0 Register. 5. Configure the associated GPIO port pin for the Timer Input alternate function. 6. Write to the Timer Control Register to enable the timer. 7. Counting begins on the first appropriate transition of the Timer Input signal. No inter- rupt is generated by this first edge. In CAPTURE/COMPARE Mode, the elapsed time from timer start to Capture event can be calculated using the following equation: Reading the Timer Count Values The current count value in the timers can be read while counting (enabled). This capability has no effect on timer operation. When the timer is enabled and the Timer High Byte Reg- ister is read, the contents of the Timer Low Byte Register are placed in a holding register. A subsequent read from the Timer Low Byte Register returns the value in the holding reg- ister. This operation allows accurate reads of the full 16-bit timer count value while enabled. When the timers are not enabled, a read from the Timer Low Byte Register returns the actual value in the counter. Timer Pin Signal Operation The timer output function is a GPIO port pin alternate function. The Timer Output is tog- gled every time the counter is reloaded. Capture Elapsed Time (s) Capture Value Start Value – Prescale System Clock Frequency (Hz) ---------------------------------------------------------------------------------------------------------------------- = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |