| 数据搜索系统,热门电子元器件搜索 |
|
STR720 数据表(PDF) 154 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STR720 数据表(HTML) 154 Page - STMicroelectronics |
|
154 / 401 page ![]() STR720 - REAL TIME CLOCK (RTC) 154/401 Bit 2 = PERIR: PERiodic Interrupt Request This bit stores the status of periodic interrupt request signal (RTC_PerIT) generated by the 20 bit programmable counter when the threshold set in RTCP register is reached. When this bit is at ‘1’, the corresponding interrupt will be generated only if PEREN bit is set to ‘1’. PERIR bit can be set at ‘1’ only by hardware and can be cleared only by software, while writing ‘1’ will left it unchanged. 0: Periodic interrupt condition not met. 1: Periodic interrupt request pending. Bit 1 = AIR: Alarm Interrupt Request This bit contains the status of periodic interrupt request signal (RTC_AlarmIT) generated by the 48 bit programmable counter when the threshold set in RTCA register is reached. When this bit is at ‘1’, the corresponding interrupt will be generated only if AEN bit is set to ‘1’. AIR bit can be set at ‘1’ only by hardware and can be cleared only by software, while writing ‘1’ will left it unchanged. 0: Alarm interrupt condition not met. 1: Alarm interrupt request pending. Note The alarm event generated during the standby mode (and so with the device kept under Reset by external RSTIN forced low) does not set the AIR bit. Note Any alarm event generated during STOP mode occurs after 1s regardless of the value programmed in the RTCA register. Bit 0 = Reserved. This bits must always be written to ‘0’, but it will be read back as ‘1’. Any interrupt request remains pending until the appropriate RTCCR request bit is reset by software, notifying that the interrupt request has been granted. RTCCNT: RTC Counter registers The RTC counter has three 16 bit programmable counters; their count rate is based on the CLK_AF time reference. RTCCNT registers keep the counting value of these counters. They are write protected by bit RTOFF of RTCCR register, write operation is allowed if RTOFF value is ‘1’. A write operation on any of the three registers (CNT_H, CNT_M or CNT_L) loads directly the corresponding programmable counter. When reading, the current value in the counter (system date) is returned. The counters keep on running while the external clock oscillator is working even if the system is powered down. 1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |