47 / 117 page ![]() ATQ_CNT Load Torque AMAX AMIN TMIN TMAX I1 I2 ATQ_UL T1 T2 ATQ_LL I3 I4 I5 I1 < I2 < I3 < I4 < I5 Figure 7-26. ATQ_CNT as a function of load torque The auto-torque algorithm confines the ATQ_CNT within the hysteretic band defined by the user programmable ATQ_UL and ATQ_LL parameters, by modulating the motor current, as shown in Figure 7-26. • If load torque demand increases (T1 to T2), the ATQ_CNT goes above the ATQ_UL threshold, and in response, the algorithm brings the ATQ_CNT within the band by increasing the current (I3 to I4). • When load torque demand drops (T2 to T1) and ATQ_CNT goes below ATQ_LL, the algorithm reduces the current to bring the ATQ_CNT within the hysteretic band (I5 to I4). The following methodology explains how user should select the values of the current control parameters - • ATQ_TRQ_MIN is the minimum motor current needed to support the minimum load torque applied to the motor. To find this parameter - – Load the motor with minimum load torque (TMIN) and drive the motor with full-scale current (IFS) – Set ATQ_UL and ATQ_LL to zero and set KP as 1 – Reduce current till the motor stalls – Note the current (IA) at which the motor stalls – Set ATQ_TRQ_MIN = 1.1 x IA • To find ATQ_TRQ_MAX - – With the motor current at IA, load the motor with maximum load torque (TMAX). The motor will get stalled. – Start increasing the motor current – Note the current (IB) at which the motor comes out of stall – Set ATQ_TRQ_MAX = 1.1 x IB – Note the ATQ_CNT (AMAX) with current at ATQ_TRQ_MAX and load torque at TMAX. • For the ATQ_UL - – Set an initial value of 0.5 x AMAX. – Apply the load profile (peak load and idle load) specific to the application. • If the motor stalls, decrease the value ATQ_UL till the motor is no longer stalled. • If the motor does not stall after applying the load profile, ATQ_UL can be increased till the motor stalls. – Higher value of ATQ_UL saves more power at peak load, but in case of a fast load transient, the motor can stall. – Lower value of ATQ_UL reduces the power saving at peak load, but also reduces the chances of motor stall and step loss. • For most applications, a difference of 2 between ATQ_UL and ATQ_LL is a good starting point. • VM_SCALE bit should be made 1b only after ATQ_UL and ATQ_LL have been set by the user. The flowchart for selecting ATQ_UL, ATQ_LL, ATQ_TRQ_MAX and ATQ_TRQ_MIN parameters is shown below. www.ti.com DRV8461 SLOSE98 – DECEMBER 2022 Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 47 Product Folder Links: DRV8461 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |